Figure 11 Example of a Log Displayed on the RAID Manager Window

2.

Locate the SSB1 and SSB2 codes. In the example above, the error codes appear on the right
of "SSB=".

The last four digits on the left of the comma (,) indicates the SSB1 code (B9E1)

The last four digits on the right of the comma (,) indicates the SSB2 code (B901)

3.

Locate the description of the SSB1/SSB2 error code combination in the following table. For
error codes not described in this table, contact HP Technical Support.

To identify an error using the RAID Manager operation log file

1.

Open the RAID Manager log file, whose default location is:

/HORCM/log*/curlog/horcmlog_HOST/horcm.log

where:

*

is the instance number.

HOST

is the host name.

2.

Find the error code. An example error code string is:

11:06:03-37897-10413- SSB = 0xB901,4A96

3.

Locate the SSB1 and SSB2 codes. In the example above, these codes appear to the right of
the equal symbol (=).

The last four digits on the left of the comma (,) are the SSB1 code (B901).

The characters right of the comma (,) are the SSB2 code (4A96).

4.

Locate the description of the SSB1/SSB2 error code combination in the following table.

For details about error codes not described in the table, contact HP Technical Support.

Table 21 RAID Manager error codes for SSB1: B901, B9A8, B9A9, B9AD, B9AE

Cause of Error

RAID Manager
Command

SSB2

Because of the shortage of the pair tables, Snapshot pair cannot be created.

paircreate

9685

Because of the shortage of the differential tables, Snapshot pair cannot be
created.

paircreate

9686

Since the pool is not available, Snapshot pair cannot be created.

paircreate

9700

When you create multiple Snapshot pairs by specifying multiple S-VOLs for one
P-VOL, you specified the pool ID that is different from the pool ID used by the
pairs that are already created. Therefore, Snapshot pair cannot be created.

paircreate

9702

Since the volume you specified as the P-VOL is already used by other Snapshot
S-VOL, the pair cannot be created.

paircreate

9703

Since the volume you specified as the S-VOL is already used by other Snapshot
P-VOL, the pair cannot be created.

paircreate

9704

Since the volume you specified as the S-VOL is already used by other Snapshot
S-VOL, the pair cannot be created.

paircreate

9705

Since the specified Snapshot ID is already used by other Snapshot pair, the pair
cannot be created.

paircreate

9706

Troubleshooting with RAID Manager

47