beautypg.com

HP XP P9500 Storage User Manual

Page 263

background image

Displayed Item

Description

No

summary

displayed

Summary

displayed

One of the following values is displayed for each path:

-
Indicates that intermittent error monitoring is disabled or

the monitoring time for an intermittent error is out of

range.

A value of at least 0
Indicates the number of errors that occurred during

intermittent error monitoring.

*
Indicates that an intermittent error occurred (automatic

failbacks do not check the path).

HBAPortWW
N

#1

-

A 16-digit hexadecimal number indicating the WWN

information for an HBA connected to the storage system.
This item is displayed only when you specify -iem together

with the -hbaportwwn parameter.

Physical-
DskName

-

When a path is migrated using a virtual ID, displays the name

of the storage system that is connected by the migration-

destination path.
A storage system name consists of the following three

elements, separated by periods:

Vendor ID: The name of the storage system vendor.

Product ID: Indicates the storage system product ID,

emulation type, or model name.

Serial number: The serial number of the storage system.

When a virtual ID is not used, a hyphen (-) is displayed.

Physical-
iLU

-

When a path is migrated using a virtual ID, displays LU

number in the storage system that is connected by the

migration-destination path.

For HUS VM, indicated by a hexadecimal number. The first

two characters of iLU are the CU number, and the last two

characters are the internal LU number within the CU.

For Hitachi Virtual Storage Platform, indicated by a

hexadecimal number. The first two characters of iLU are

the number of the logical DKC (Disk Controller), the

middle two numbers are the CU number, and the last two

characters are the internal LU number within the CU.

When a virtual ID is not used, a hyphen (-) is displayed.

Physical-
ChaPort

-

When a path is migrated using a virtual ID, displays port

number of the CHA that is connected by the migration-

destination path.
When a virtual ID is not used, a hyphen (-) is displayed.

Legend:

-: Not displayed

Command Reference

6-51

Hitachi Dynamic Link Manager User Guide for AIX

®

This manual is related to the following products: