Changing the Number of Integrated Trace Files

The following procedure shows how to change the number of integrated trace

files.

To change the number of integrated trace files:

1

.

In the Hitachi Network Objectplaza Trace Library setup menu, type 2 and

then press the Enter key.
A screen to set the number of integrated trace files will appear. The

current value is displayed in Current Number (KB).

2

.

Enter the desired number in New Number (KB).
You can specify a value from 1 to 16. The default is 4. The value set here

becomes the maximum of n in /var/opt/hitachi/HNTRLib2/spool/
hntr2n.log. The recommended value for integrated trace collection is 8.
If you do not want to change the number of integrated trace files, leave

New Number (KB) blank, type !, and then press the Enter key to

return to the Hitachi Network Objectplaza Trace Library setup menu.

3

.

Press the Enter key.
The new setting is applied and the Hitachi Network Objectplaza Trace

Library setup menu appears again.

Changing the Buffer Size Per Monitoring Interval Duration

The following procedure shows how to change the buffer size per monitoring

interval.

To change the buffer size per monitoring interval:

1

.

In the Hitachi Network Objectplaza Trace Library setup menu, type 4 and

then press the Enter key.
A screen to set the buffer size will appear. The current value is displayed

in Current Size (KB).

2

.

Enter the desired size in New Size (KB).
Set a new buffer size to fit the monitoring interval set in 5: Interval

Timer. The specifiable range is between 8 KB and 2048 KB, with a default

3-86

Creating an HDLM Environment

Hitachi Dynamic Link Manager User Guide for AIX

®