HP Surestore 2.28 Tape Library User Manual
Page 85
4-41
Library Operation
Using Online Repair
L
ib
r
ar
y
O
p
er
at
io
n
6. Press
NEXT
until
DRV # OFF FAILED
displays then press
ENTER
.
7.
CHANGE CONFIRMED
displays briefly, then
ONLINE REPAIR*
displays. Press
ENTER
.
8.
DRIVE POWER*
displays.
9. Press
NEXT
or
PREV
until
DRIVE STATUS
displays, then press
ENTER
.
10. Press
NEXT
or
PREV
until
DRV # OFF FAILED
displays (where “#” is the
number of the drive that was just taken offline) then press
ENTER
.
11.
DRV # OFF FAILED
displays, where “#” is the drive number and “OFF
FAILED” is flashing.
12. Press
NEXT
until
DRV # ON GOOD
displays, then press
ENTER
.
13.
SETTING UP DRIVE
displays briefly while the drive communication
tests run, then
CHANGE CONFIRMED
displays briefly, then
ONLINE
REPAIR*
displays.
14. Press
CANCEL
twice to return to the drive numbers and status indicators
(“ready” state).
15. Try reading the damaged tape again.
•
If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.
•
If the tape cannot be read, call a service representative.