Setting the robotics controller bus type – HP Surestore 2.28 Tape Library User Manual
Page 57
![background image](/manuals/397395/57/background.png)
4-13
Library Operation
Specifying SCSI Addresses
L
ib
r
ar
y
O
p
er
at
io
n
Setting the Robotics Controller Bus Type
1 2 3 4
➔
ADMIN*
➔
PSWD 000-000-000
➔
SCSI IDs*
➔
SET LIB
BUS*
Two bus settings are available:
•
Differential
•
Single-ended
To set the bus type:
1. Verify that the drive status displays (if not, press
CANCEL
until it does).
2. Press
NEXT
until
ADMIN*
displays, then press
ENTER
.
3. Enter the three-part numerical password (see “Entering the
Administration Menu Password” on page 4-7).
4. Press
NEXT
until
SCSI IDs*
displays, then press
ENTER
.
5. Press
NEXT
until
SET LIB BUS*
displays, then press
ENTER
.
DIFFERENTIAL
displays.
6. Press
NEXT
to toggle between
DIFFERENTIAL
or
SINGLE ENDED
. Press
ENTER
to set the bus type.
DIFFERENTIAL BUS
or
SINGLE ENDED BUS
displays briefly, then
SCSI IDs*
displays.
7. Press
CANCEL
until the next operation to perform displays, or until the
drive status (library “ready” state) displays.