Setting the robotics controller bus type – HP Surestore 2.28 Tape Library User Manual

Page 57

background image

4-13

Library Operation

Specifying SCSI Addresses

L

ib

r

ar
y

O
p

er
at
io

n

Setting the Robotics Controller Bus Type

1 2 3 4

ADMIN*

PSWD 000-000-000

SCSI IDs*

SET LIB

BUS*

Two bus settings are available:

Differential

Single-ended

To set the bus type:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.

3. Enter the three-part numerical password (see “Entering the

Administration Menu Password” on page 4-7).

4. Press

NEXT

until

SCSI IDs*

displays, then press

ENTER

.

5. Press

NEXT

until

SET LIB BUS*

displays, then press

ENTER

.

DIFFERENTIAL

displays.

6. Press

NEXT

to toggle between

DIFFERENTIAL

or

SINGLE ENDED

. Press

ENTER

to set the bus type.

DIFFERENTIAL BUS

or

SINGLE ENDED BUS

displays briefly, then

SCSI IDs*

displays.

7. Press

CANCEL

until the next operation to perform displays, or until the

drive status (library “ready” state) displays.