beautypg.com

HP Surestore 2.28 Tape Library User Manual

Page 72

background image

4-28

Library Operation

Clearing a Drive Cleaning Error

DRV # ON GOOD

displays, where “#” is the drive number and

ON GOOD

is flashing.

6. Press

NEXT

until

DRV # OFF FAILED

displays then press

ENTER

.

7.

CHANGE CONFIRMED

displays briefly, then

ONLINE REPAIR*

displays. Press

ENTER

.

8.

DRIVE POWER*

displays.

9. Press

NEXT

or

PREV

until

DRIVE STATUS

displays, then press

ENTER

.

10. Press

NEXT

or

PREV

until

DRV # OFF FAILED

displays (where “#” is the

number of the drive that was just taken off-line) then press

ENTER

.

11.

DRV # OFF FAILED

displays, where “#” is the drive number and “OFF

FAILED” is flashing.

12. Press

NEXT

until

DRV # ON GOOD

displays, then press

ENTER

.

13.

SETTING UP DRIVE

displays briefly while the drive communication

tests run, then

CHANGE CONFIRMED

displays briefly, then

ONLINE

REPAIR*

displays.

14. Press

CANCEL

twice to return to the drive numbers and status indicators

(“ready” state).

15. Try reading the damaged tape again.

If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.

If the tape cannot be read, call a service representative.

If the tape can be read, back up data from the damaged cartridge to
another tape cartridge and discard the damaged one.

This manual is related to the following products: