Library Operation

Running an Internal Test

L

ib

r

ar
y

O
p

er
at
io

n

Table 4-10

Tests Available from the Control Panel

Test Name

Description

EXERCISE MECH

Runs the VERTICAL TEST, TRANSLATE TEST, MAGAZINE IO,
DRIVE IO, and MAILSLOT IO tests. Each test is run one time per test loop.

EXCHANGE DEMO

Do not run test if library contains customer data cartridges.

Moves randomly-chosen cartridges to random storage slot locations. This test
displays FAIL if there are no cartridges in the library or if all storage slots are
full. For best results, the library should contain as many cartridges as there are
drives, plus two additional cartridges. The transport and mailslot must be empty.

IO DRIVE

Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly- chosen full slot to a randomly-chosen drive. It then
moves the cartridge back to its original slot. This test displays FAIL if there are
no cartridges in the library or if all storage slots are full. The drives, transport,
and mailslot must be empty.

IO MAGAZINE

Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to a randomly-chosen empty slot. It
then moves the tape back to its original storage slot. This test displays FAIL if
there are no cartridges in the library or if all storage slots are full. The drives,
transport, and mailslot must be empty.

IO MAILSLOT

Makes a combination of moves with a PASS/FAIL result. It moves a tape
cartridge from a randomly-chosen full slot to the mailslot. It then moves the
cartridge back to its original slot. This test displays FAIL if there are no
cartridges in the library or if all storage slots are full. The drives, transport, and
mailslot must be empty.

INVENTORY
CHECK

Functions the same as the SCSI Initialize Element Status (ISTAT) command.
This test physically scans the entire unit to determine which storage slots contain
tape cartridges and if the drives contain cartridges. NOTE: This test appears as
“INVENTORY CHECK” in all control panel error messages.

TEST
TRANSLATE

Translates from side to side. No tape cartridges are required.

TEST VERTICAL

Moves the transport mechanism up and down the full length of the rail.
Returns PASS/FAIL. No tape cartridges are required.

WELLNESS TEST

Checks out the general capability of the library. Runs INIT MECHANICS
and EXERCISE MECH. Each test is run one time per test loop.