4-11

Library Operation

Specifying SCSI Addresses

L

ib

r

ar
y

O
p

er
at
io

n

5.

SET IDs*

displays. Press

ENTER

.

LIB BUS0 ID #

or

DRV# BUS# ID #

displays. (LIB BUS0 ID # stands

for the current SCSI ID of the robotics controller.
DRV# BUS# ID # is the current SCSI ID setting for the drive number and
its associated bus #.)

6. Press

NEXT

until the setting to change displays, then press

ENTER

.

7. The current SCSI address setting flashes. Press

NEXT

or

PREV

until the

desired address displays, then press

ENTER

.

8. Press

NEXT

until

UPDATE IDs NOW

displays, then press

ENTER

.

9.

WAIT FOR UPDATE

displays briefly, then

IDs SAVED

displays.

If the new settings do not conflict with other SCSI IDs on the bus,

SCSI IDs*

displays.

If the new settings conflict with other IDs on the SCSI bus,

CONFLICT

ABORTED

displays briefly, then

SET IDs*

displays. Any changes

entered are lost, and previous steps must be repeated to set a new
address.

If any buses are daisy chained together, make sure the SCSI IDs are
different for each device on the bus.

If a serial communications error is detected while trying to set the
SCSI IDs,

DRV CONNECT ERR

displays, followed by

IDs NOT

CHANGED

. Any changes entered are lost. The

SCSI IDs*

menu

displays.

10. Press

CANCEL

three times to return to the drive status (“ready” state).

11. New settings can be saved to flash ROM. Turn the library off, then turn it

back on. This allows the settings to be recovered if the library is powered
off for more than ten days.

NOTE

After you change an address, it may be necessary to reboot the host. This
allows the new SCSI IDs to be recognized.