Specifying SCSI Addresses

Viewing the Current SCSI Address Settings

1 2 3 4

ADMIN*

PSWD 000-000-000

SCSI IDs*

VIEW IDs*

To view the current SCSI address settings:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.

3. Enter the three-part numerical password (see “Entering the

Administration Menu Password” on page 4-7).

4. Press

NEXT

until

SCSI IDs*

displays, then press

ENTER

.

5.

SET IDs*

displays. Press

NEXT

until

VIEW IDs*

displays, then press

ENTER

.

6.

BUS0 LIB ID#

or

BUS# DRV * ID *

displays. (BUS0 LIB ID # stands

for the current SCSI ID of the robotics controller.
BUS# DRV # ID # is the current SCSI ID setting for the displayed drive
number and its associated BUS#.)

Press

NEXT

or

PREV

to scroll through the current address settings.

7. Press

CANCEL

until the next operation to perform displays, or until the

drive status (library “ready” state) displays.

Setting the SCSI Addresses

1 2 3 4

ADMIN*

PSWD 000-000-000

SCSI IDs*

SET IDs*

A SCSI address is required for the robotics controller and each tape drive.
For more information, see Table 4-2, “Default SCSI Address Settings” on page
4-9, and the section “Viewing the Current SCSI Address Settings” on page
4-10.

To change the current SCSI address settings:

1. Verify that the drive status displays (if not, press

CANCEL

until it does).

2. Press

NEXT

until

ADMIN*

displays, then press

ENTER

.

3. Enter the three-part numerical password (see “Entering the

Administration Menu Password” on page 4-7).

4. Press

NEXT

until

SCSI IDs*

displays, then press

ENTER

.