Clearing a drive cleaning error – HP Surestore 2.28 Tape Library User Manual
Page 71

4-27
Library Operation
Clearing a Drive Cleaning Error
L
ib
r
ar
y
O
p
er
at
io
n
Clearing a Drive Cleaning Error
1 2
➔
ADMIN*
➔
PSWD 000 000 000
➔
ONLINE REPAIR
CAUTION
The library drive mechanism(s) are inactive while this option is in use.
To use on-line repair to clear a drive cleaning error:
1. With
CLEAN DRV #
displayed, press
CANCEL
until the drive status
displays. (# is the drive number containing the damaged tape.)
2. Press
NEXT
until
ADMIN*
displays, then press
ENTER
.
3. Enter the three-part numerical password (see “Entering the
Administration Menu Password” on page 3-7).
4.
INFO*
displays. Press
NEXT
or
PREV
until
ONLINE REPAIR*
displays,
then press
ENTER
.
DRIVE POWER*
displays.
5. Press
NEXT
or
PREV
until
DRIVE STATUS
displays, then press
ENTER
.
DRV
1 ON GOOD
displays.
•
If the damaged tape is in drive 1, press
ENTER
.
•
If the damaged tape is in drive 2, press
NEXT
until
DRV 2 ON GOOD
displays, then press
ENTER
.