State event messages for overall status policy – HP Insight Control User Manual
Page 61
Appendix A - Insight Integration state change messages 61
oldState value
newState value
CriticalAcknowledged
•
Repaired
•
Warning
WarningAcknowledged
•
Repaired
•
Broken
Down
•
Repaired
•
Warning
•
Broken
Broken
•
Repaired
•
Warning
Unknown
•
Up
•
Warning
•
Broken
Repaired
•
Warning
•
Broken
Up
•
Warning
•
Broken
Warning
•
Repaired
•
Broken
The following are polling state change message examples:
•
161 ( ClassName = cpqScsiMibCnd_FSM oldState = Up newState = Broken )
•
161 ( ClassName = ScsiCntrl_FSM oldState = Up newState = Broken )
•
161 ( ClassName = cpqScsiMibCnd_FSM oldState = Broken newState = Repaired )
•
161 ( ClassName = ScsiCntrl_FSM oldState = Broken newState = Repaired )
The following are acknowledge state change examples:
•
( ClassName = HealthStatFSM oldState = Broken newState = CriticalAcknowledged )
•
( ClassName = HealthStatFSM oldState = Warning newState = WarningAcknowledged )
•
( ClassName = ScsiCntrl_FSM oldState = Repaired newState = Up )
State event messages for Overall Status Policy
The following state event messages are defined in the InsightManager.dat file for the Overall Status
Policy:
•
HP_HostOS_Status:\$event:\$oldState:\$newState:$hostName $reason
•
HP_Health_Status:\$event:\$oldState:\$newState:$hostName $reason
•
HP_StandardEquipment_Status:\$event:\$oldState:\$newState:$hostName $reason
•
HP_SystemInfo_Status:\$event:\$oldState:\$newState:$hostName $reason
•
HP_SCSI_Status:\$event:\$oldState:\$newState:$hostName $reason
•
HP_DriveArray_Status:\$event:\$oldState:\$newState:$hostName $reason