HP Insight Control User Manual
Page 45
Using the software 45
3.
Run the hpqclassremove.exe program.
To use the new menu definitions, right-click an icon, and select the appropriate menu option (HP System
Management Homepage is selected in the following example).
Generating event messages from HP Systems Insight
Manager
In addition to the HP message record and DSM policy capabilities, integrating HP hardware management
events into the Unicenter Event Console can also be achieved by forwarding events directly from HP
Systems Insight Manager. You can use this solution as an integration alternative to message records and
DSM policy event management.
Completing the following procedure enables the display of HP events in the Unicenter Event Management
Console as they appear in HP Systems Insight Manager. Some additional event translation and severity
details, provided with HP message records and DSM policies for Unicenter, might not display.
To enable event message generation from HP Systems Insight Manager:
1.
Copy the hpsimnsm.exe and hpsimnsm.cmd files from the \hpsim directory to the Unicenter\bin
directory, for example C:\Program Files\CA\SC\CCS\WVEM\BIN on the HPSIM server. At
minimum, the Unicenter Event Agent should be installed on the HPSIM server. This will provide
access to the Unicenter NSM Components - Enterprise Management - Event Management - Event
Management Base component.