HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 91
Storage management 91
•
Multi-enclosure domain
The following table describes the columns and fields within the Define SAN Fabric screen.
Column Description
Fabric Name
Descriptive name for the virtual fabric. Do not use spaces.
Configured Speed
Speed of the uplink port(s)
Uplink Port
Number of the enclosure uplink port
Enclosure
(Multi-enclosure domains only) Name of the enclosure selected for the SAN fabric.
Bay
Enclosure bay selected for the SAN fabric. Only uplinks on the same bay can be in
the same SAN fabric.
Port
(Single enclosure domains only) Port number
Port Status
Status of the uplink port
Speed
Port speed for the uplink ports in the fabric
Connected To
WWN of the principal switch on the SAN fabric that this port is connected to on
the other end.
Delete When
the
X in the column is bold, this line item is eligible for deletion.
The following table describes the available actions in the Define SAN Fabric screen. Clicking another link
in the pull-down menu or left navigation window causes the current edits that have not been applied to be
lost.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem