beautypg.com

Interconnect bay vc status icon definitions – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 154

background image

Hardware information screens 154

Interconnect Bay VC Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Unknown

Device operational state cannot
be determined.

Check Onboard Administrator
communication.

Disabled

User has administratively

disabled the device.

Enable the component in Virtual

Connect Manager.

(blue)

Initializing Device

is

initializing. Wait until initialization is complete.

(This icon should only be seen at
startup.)

(blue)

Unavailable

Device is active but unable to

provide service.

Attempt to re-establish connection.

(yellow
)

Degraded

Device is partially operational,
but capacity is lost.

Check and correct the Onboard
Administrator error condition.

(orang
e)

Misconfigured

Device has a configuration error.

Correct the Virtual Connect Manager
configuration attributes.

(orang

e)

Incompatible

Device does not match the

configuration.

Remove the incorrect hardware.

Insert the correct module.

(orang

e)

No communication

Cannot communicate with the

device.

Check the physical connections and

IP address.

Missing

Device is configured but not
accessible.

Insert the correct hardware module.

Failed

Device is not operational because
of an error.

Reset the device or application, or
replace the device.

Interconnect Bay OA Communication Status icon definitions

Icon

Operational state

Meaning

Corrective action

OK

Device is fully operational.

None

Failed

Cannot communicate with the

device.

Do one or more of the following:

Reset the interconnect module.

Check if the physical device is

properly seated in the bay.

Check the IP address.