Interconnect bay overall status icon definitions – HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual
Page 153
Hardware information screens 153
If these conditions are not met, the Remove from Domain button is not available, or an error message
appears.
If a VC-Enet module is restarted from a power-cycle or reboot, or the module is removed and inserted, a
link might not be re-established between the module and the ports of an NC364m mezzanine card. If the
server is rebooted, the link is established on all ports on both sides of the connection. Manually toggling
the link from the server should also restore the link.
Interconnect Bay Overall Status icon definitions
Icon
Operational state
Meaning
Corrective action
OK
Device is fully operational.
None
Unknown
Device operational state cannot
be determined.
Check Onboard Administrator
communication.
(blue)
Initializing Device
is
initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(yellow
)
Degraded
Device is partially operational,
but capability is lost.
Check and correct the Onboard
Administrator error condition.
(orang
e)
Misconfigured
Device has a configuration error.
Correct the Virtual Connect Manager
configuration attributes.
(orang
e)
Incompatible
Device does not match the
configuration.
Remove the incorrect hardware.
Insert the correct module.
(orang
e)
No communication
Cannot communicate with the
device.
Check the physical connections and
IP address.
Missing
Device is configured but not
accessible.
Insert the correct hardware module.
Failed
Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Interconnect Bay OA Reported Status icon definitions
Icon
Operational state
Meaning
Corrective action
OK
Device is fully operational.
None
Unknown
Device operational state cannot
be determined.
Check Onboard Administrator
communication.
(yellow
)
Degraded
Device is partially operational,
but capacity is lost.
Check and correct the Onboard
Administrator error condition.
Failed
Device is not operational because
of an error.
Check and correct the Onboard
Administrator error condition.
- Virtual Connect 4Gb Fibre Channel Module for c-Class BladeSystem 4GB Virtual Connect Fibre Channel Module for c-Class BladeSystem Virtual Connect 8Gb 20-port Fibre Channel Module for c-Class BladeSystem Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem 1.10GB Virtual Connect Ethernet Module for c-Class BladeSystem Virtual Connect 8Gb 24-port Fibre Channel Module for c-Class BladeSystem