beautypg.com

HP Virtual Connect Flex-10 10Gb Ethernet Module for c-Class BladeSystem User Manual

Page 70

background image

Network management 70

Field name

Description

Direction

Direction of traffic on the port being monitored. Valid choices are From
Server, To Server, or Both. The default is Both.

Server Profile

Identifies the server profile associated with the monitored port if one
exists.

Port

Enclosure, bay, and port number of monitored port

MAC

MAC address of monitored port

Server Bay Assignment

Enclosure and server device bay the monitored port is associated with

Network

Network associated with the downlink port, if one exists

Delete

Displays Delete icon. Click to remove the port from the monitored list.

The following table describes the available actions in the Ethernet Settings (Port Monitoring) screen.

Clicking another link in the pull-down menu or left navigation window causes current edits that have not

been applied to be lost.

Task Action

Enable or disable port
monitoring

Click the drop-down box under Port Monitoring State.

Select a mirror-to port

Click the down arrow in the Add Port box. The current network
analyzer port must be deleted before a new one can be selected.

Change the Network Analyzer
Port speed

Click the drop-down box under Speed/Duplex, and then select a
setting.

Delete the Network Analyzer

Port

Click the Delete icon.

View detailed statistics for the

Network Analyzer Port

Click on the Detailed Statistics link.

Add a port to the monitored
port list

Click Select Port.... A list of server ports is displayed with checkboxes
to select or deselect the monitored ports.

Clear selections and settings
without saving

Click Clear.

Apply new selections and
settings

Click Apply.

Clear selections and settings

without saving and return to the
Virtual Connect homepage

Click Cancel.