Comments, 44 sample index and parameter definitions, 45 sample configuration definitions – HP XP Array Manager Software User Manual
Page 89: Figure 45, Figure 44
•
Do not write the identical index more than once in the same function tag.
•
To change some, but not all, of the settings on the same configuration definitions, you must copy
and paste the settings that you do not want to change to the new settings area. Otherwise,
those settings will be processed as deleted.
on page 89 shows an example of index and parameter definitions.
[Cha]
# Cha
PcbMode
・・・
Cha
PcbMode
・・・
CHA-1P HighSpeed
CHA-1P Standard
CHA-1Q Standard
CHA-1Q HighSpeed
Index (unalterable)
Parameter(alterable)
Figure 44 Sample Index and Parameter Definitions
Figure 45
on page 89 shows sample configuration definition settings.
[Port]
・・・
・・・
1A Off EF ・・・ 1A
On
EF
・・・
・・・
・・・
・・・
・・・
Current Settings Area
New Settings Area
Function Tag
Configuration Definition
(Settings)
3 Blank Columns (from 8th to 10th column)
Figure 45 Sample Configuration Definitions
Comments
You can also type comment rows in the spreadsheet by beginning a row with the # character. The
comment row can consist of any characters in any language. A row that includes only a linefeed code is
also recognized as a comment row.
•
Example:
# (comment)
# Change CHA settings (comment)
[Cha](function tag)
# Cha, PcbMode (comment)
# (linefeed)
# (linefeed)
CHA-1P,Standard (indicating changes)
CHA-1Q,Standard (indicating changes)
XP24000 LUN Manager User's Guide