Setup
Reader
V
iewer
Online
Template
The template, selected via
Setting > LOG-HC2 (* .mse), defines which
sensors the
Reader reads out as standard or are displayed in Online . The
template sets the colour of the trace, the positioning of its axis (left, right)
and gives the sensors a name (“HUM, T1” is required to be displayed as
“outside temperature”, for example) . Templates can be produced on the
basis of examples contained in
Viewer (->34) .
Example
The temperature curves are required to be blue and oriented on the right
hand axis in all display modes .
1 . Assign right hand axis and blue colour shades to temperature in
Viewer .
2 . Save as template (Bluetemp .mse) .
3 . Generate new templates for
Reader and Online: Select logger program
window,
Settings LOG-HC2 > Template , enter new name and path
(Temperature .mse), then
Open .
4 . Open the still blank template (Temperature .mse) using .
5 .
Import the template that was created in Viewer (Bluetemp .mse) .
Select the required sensors (tick in checkbox) in the
Module column and
confirm with
Accept .
6 . Edit the displayed list: First select a sensor in the Module column and
then choose
Edit .
7 . Change the name “HUM, T1” to “Outside temperature”, and Accept .
8 . Continue to make the necessary adjustments and confirm them with
Accept .