Table 3-4: I/O Characteristics

Parameter

Value

Communication Interface

RS232 UART & USB

Communication Protocol

PNI Binary

Communication Rate

1

2400 to 921,600 baud

Maximum Data Output Rate

≈30 samples/sec

Footnote:

1. The TRAX can operate up to 921,600 baud, but native RS232 is limited to

115,200 baud.

Table 3-5: Environmental Requirements

Parameter

Value

Operating Temperature

1

-40C to +85C

Storage Temperature

-40C to +85C

Footnote:

1. To meet performance specifications across this range, recalibration will be

necessary as the temperature varies.

Table 3-6: Mechanical Characteristics

Parameter

Value

Dimensions
(l x w x h)

TRAX Enclosed 6.4 x 5.9 x 2.3 cm
TRAX PCA

3.5 x 4.3 x 1.0 cm

Weight

TRAX Enclosed 75 gm
TRAX PCA

7 gm

Connector

TRAX Enclosed 7 pin ODU, pn K20L0C-P07LCC0-520S
TRAX PCA

9-pin Molex, pn 53780-0970