Table 3-2: absolute maximum ratings, Table 3-3: electrical requirements – PNI FieldForce Trax User Manual
Page 8
PNI Sensor Corporation
DOC#1016505 r06
TRAX User Manual
Page 4
Table 3-2: Absolute Maximum Ratings
Parameter
Minimum
Maximum
Units
Supply Voltage
-0.3
+10
VDC
Storage Temperature
-40
+85
°C
CAUTION:
Stresses beyond those listed above may cause permanent damage to the device.
These are stress ratings only. Operation of the device at these or other conditions
beyond those indicated in the operational sections of the specifications is not implied.
Table 3-3: Electrical Requirements
Parameter
Value
Supply Voltage
3.8 to 9 VDC
Communication Lines
High Level Input
2.4 V minimum
Low Level Input
0.6 V maximum
Output Voltage Swing
±5.2 V typ., ±5.0 V min.
Tx Output Resistance
300 Ω
Current Draw
AHRS Mode@ max.
sample rate
55 mA typical
Compass Mode @
max. sample rate
28 mA typical
During application of
external power
See Figure 3-1
Sleep Mode
0.5 mA typical
Figure 3-1: Typical Current Drawing During Application of External Power