Page 24

6.4.1

General Settings

Baud Rate

The baud rate can be altered by selecting the desired baud rate from the pull down
menu, clicking on “Save”, and then powering the device off and back on. The new
baud rate will not take effect until the device has been powered off/on. The default

baud rate is 38400.

Mounting

TRAX Studio supports 16 mounting orientations, as previously illustrated in Figure

4-2. The default is “Standard”.

Output Units

The TRAX can output heading, pitch, and roll in either degrees or mils. The default
is “Degrees”. (There are 6400 mils in a circle, such that 1 degree = 17.7778 mils and
1 mil = 0.05625 degree.)

North Reference

When “Magnetic” is selected, the heading output will be relative to magnetic north.

When “True” is selected, heading will be relative to true north, and the declination

value should be entered in the next field. The default is “Magnetic”.