7.6 Calibration Commands

7.6.1

User Calibration Commands

First, note that in order to perform a user calibration, it is necessary to place the TRAX in

Compass Mode, as discussed in Section 7.7. Note that TRAX allows for a maximum of

12 calibration points.

kStartCal (frame ID 10

d

)

This frame commands the TRAX to start user calibration with the current sensor

acquisition parameters, internal configurations and FIR filter settings.

Note: The payload needs to be 32 bit (4 byte). If no payload is entered or if less than 4 bytes
are entered, the unit will default to the previous calibration method.

The CalOption values are given below, along with basic descriptions of the options.

Full-Range Calibration

Recommended calibration method when >45° of tilt is possible. Can be used for

between 20° and 45° of tilt, but accuracy will not be as good

2D Calibration

Recommended when the available tilt range is limited to ≤5

°. Can be used for 5°

to 10° of tilt, but accuracy will not be as good.

Hard-Iron-Only Calibration

Recalibrates the hard-iron offset for a prior calibration. If the local field hard-iron

distortion has changed, this calibration can bring the TRAX back into

specification.

CalOption

UInt32

Payload

CalOption Payload Value:
“10

d

” or “0A

h

”: Full-Range Calibration (default)

“20

d

” or “14

h

”: 2D Calibration

“30

d

” or “1E

h

”: Hard-Iron-Only Calibration

“40

d

” or “28

h

”: Limited-Tilt Calibration

“100

d

” or “64

h

”: Accel-Only Calibration

“110

d

” or “6E

h

”: Mag-and-Accel Calibration

2

Heading ID

ID Count

Payload

Heading

(Float32)

Heading

Status ID

Heading

Status (UInt8)

5

359.9

79

1