NORD Drivesystems BU0090 User Manual
Page 38
NORDAC AS-Interface Manual
38
BU
0090
GB
Parameter
Setting value / Description / Note
Comments
P742 Database
version
0 ... 9999
Displays the internal database version of the FI.
P744 Configuration
SK 300E, SK 700E, SK 750E
This parameter displays the option modules detected by the FI.
The display with the ParameterBox is in plain text.
The possible combinations are displayed in code in the ControlBox. Both right digits indicate the
customer unit used and the two left digits indicate the special extension unit. The options vary
depending on the FI type.
Customer Unit SK CU1-…
Special extension unit SK XU1-...
0 ... 9999
No
IO
XX00
Basic
IO
XX01
Standard
IO
XX02
Multi
IO
XX03
USS
IO
XX04
CAN
IO
XX05
Profibus
IO
XX06
Encoder
01XX
PosiCon
02XX
P744 Configuration
SK 500E
This parameter displays the design status integrated in the FI. Display is in hexadecimal code
(SimpleBox, ControlBox, Bus system).
The display is in plain text when the ParameterBox is used.
0000 ... FFFF (hex)
SK 500E = 0000
SK 510E/511E/515E = 0000
SK 520E = 0101
SK 530E/535E = 0201
P745 Module
version
SK 300E, SK 500E
0.0 ... 3276.7
Design status (software version) of the technology unit (SK TU2/3-xxx), but only when a separate
processor is present, therefore not for SK TU2/3-CTR.
Have this data available if you have a technical query.
P745
... - 01
…
... - 03
Module version
SK 700E, SK 750E
0.0 ... 3276.7
Software version of the installed module
[01] Technology unit
(E.g.: AS interface Technology Unit)
[02]
Customer
Unit
[03] Special Extension Unit