5.1.4
BUS module information parameters, bus-specific (P18x)
Access: Read
only
Parameter
Setting value / Description / Note
Device
Parameter
type
P180
…
[-01]
…
…
[-07]
PPO TYPE
(PPO Type / Module ID)
SK TU3-PNT
8 Bit
The module ID (see gsdml file) for the slots can be queried with this parameter. Caution:
meaningful values can only be read out with an existing AR.
Possible values:
0 = Empty slot
1 = Reserved slot
2 = DIG-IO,
Process data for the TU
3 = PPO3,
Process data for the FI
4 = PPO4,
Process data for the FI
5 = PPO6,
Process data for the FI
6 = PPO1,
Process or parameter data for the FI
7 = PPO2,
Process or parameter data for the FI
0 ... 7
[-01] =
Reserved
[-02] =
Reserved
[-03] =
Slot 3 (FI)
[-04] =
Reserved
[-05] =
Reserved
[-06] =
Reserved
[-07] =
Reserved
P181
…
[-01]
…
…
[-06]
MAC Address
(MAC Address)
SK TU3-PNT
8 Bit
0 ... 255
The Ethernet address (MAC address) can be read out from this parameter.
[-01] … [-03]
PROFINET
identification
[-04] … [-06]
Manufacturer's address range (NORD: 6000 … 6FFF)
Example:
(00:0E:CF:03:60:00)