PROFINET bus module for NORD frequency inverters SK 5xxE

20

Subject to technical amendments

BU 0590 GB-0312

4.1.3

Status word

Bit

Value

Meaning

Remarks

0

0

Not ready to start

1

Ready to start

Initialisation completed, charging relay ON, output voltage disabled

1

0

Not ready for operation Causes: No command has been activated, fault is signaled, OFF2 or OFF3

activated, starting disabled state activated

1

Ready for operation

ON command activated, no faults present. The inverter can be started with the
command ENABLE OPERATION

2 0 Operation

disabled

1

Operation enabled

The output voltage is enabled; ramp to the existing setpoint

3 0 No

fault

1 Fault

Drive fault resulting in stoppage; this state is changed to starting disabled after
the fault has been successfully acknowledged

4

0

OFF 2

OFF2 command applied

1

No OFF 2

5

0

OFF 3

OFF3 command applied

1

No OFF 3

6

0

Starting not disabled

1

Starting disabled

Switches first to OFF1, then to ready-to-start status

7 0 No

warning

1

Warning

Drive operation continues, no acknowledgement necessary

8

0

Actual value not O.K.

Actual value does not match the setpoint (with posicon: failure to reach setpoint
position)

1

Actual value O.K.

Actual value matches required setpoint (setpoint has been reached)
(with posicon: setpoint has been reached)

9

0

Local guidance

Guidance on local device has been activated

1

Guidance requested

The master has been requested to assume guidance.

10 0

1

Bit 10 active

Bus bit 10 from the status word is set. For further details of function, please refer
to parameter P481.

11 0

1 Rotational direction:

right

Inverter output voltage is turning right

12 0

1 Rotational direction:

left

Inverter output voltage is turning left

13 0

1

Bit 13 active

Bus bit 13 from the status word is set.

For further details of function, please refer

to parameter P481.

14 0/1 Currently active

parameter set 0

15 0/1 Currently active

parameter set 1

00 = Parameter set 1
01 = Parameter set 2

10 = Parameter set 3
11 = Parameter set 4

Table 15 Meaning of individual status word bits