Parameter

{Factory setting}

Setting value / Description / Note

Device

Parameter
type

P162

Device name

(Device name)

SK TU3-PNT

8 Bit

45 ... 122

The device name can be queried or changed with this parameter. Character strings with a
length of up to 240 characters are possible. Characters 45 to 122 from the ASCII Code can be
used.

The name is saved after the entry of a 0 at the end of the character string.

P163

[-01]

[-07]

Test alarm

(Test alarm)

SK TU3-PNT

8 Bit

This parameter is used, e.g to trigger a diagnostic alarm from a slot during commissioning. A
frequency inverter error can be simulated by entering the value of the error (e.g. link circuit
overvoltage = E005.0  Value 50) in the slot of the relevant inverter (e.g.: Slot 3). An
"incoming" alarm is triggered. If the value is reset to 0 the alarm is "outgoing".

Example:

Trigger alarm with error 5.0 on Slot 2:

P163[-04] = 50  ChannelErrorType=

0x100+50=0x132

0 ... 255

all { 0 }

[-01] =

Slot 0 (DAP - reserved)

[-02] =

Slot 1 (reserved)

[-03] =

Slot 2 (TU)

[-04] =

Slot 3 (FI)

[-05] =

Slot 4 (reserved)

[-06] =

Slot 5 (reserved)

[-07] =

Slot 6 (reserved)


5.1.3

BUS module information parameters, general (P17x)

Access:

Read

only

Parameter

Setting value / Description / Note

Device

Parameter
type

P170

...

[-02]

Present error

(Present error)

SK TU3-PNT

16 bit

Actual errors in the PROFINET module. The error message is reset when the supply voltage is
switched off.

Possible error codes:

- 1020 Bus Time Out via P151 (TU4-PNT) or P513 (TU3-PNT)

0 ... 5420

[-01] =

Actual module error

[-02] =

Actual module error

P171

[-01]


[-03]

Software-Version

(Software Version / Revision)

SK TU3-PNT

16 bit

This parameter shows the software and revision numbers in the module. Array 03 provides
information about any special versions of the hardware or software A zero stands for the
standard version.

0.0 ... 9999.9

[-01] =

Version

[-02] =

Revision

[-03] =