NORD Drivesystems BU0570 User Manual
Page 30
EtherCAT bus module for NORD frequency inverters SK 5xxE
30
Subject to technical amendments
BU 0570 GB-0312
Parameter
Setting value / Description / Note
Device
Parameter
type
P176
…
[-01]
…
…
[-27]
PZD bus IN
(Process data bus IN)
SK TU3-ECT
16 bit
Allocation of process data which have been received (data sent from PROFINET IO controller).
-32768 ... 32767
[-01] =
Bus module outputs
[-02] =
Control word for FI1
[-03] =
Setpoint 1 for FI1
[-04] =
Setpoint 2 for FI1
[-05] =
Bus module outputs
[-06] =
Control word for FI1
[-07] =
Setpoint 1 for FI1
[-08] =
Setpoint 2 for FI1
P177
…
[-01]
…
…
[-27]
PZD bus OUT
(Process data bus OUT)
SK TU3-ECT
16 bit
Allocation of process data which have been transmitted (data sent to the PROFINET IO
controller).
-32768 ... 32767
[-01] =
Bus module inputs
[-02] =
Status word from FI1
[-03] =
Actual value 1 from FI1
[-04] =
Actual value 2 from FI1
[-05] =
Bus module inputs
[-06] =
Status word from FI1
[-07] =
Actual value 1 from FI1
[-08] =
Actual value 2 from FI1
5.1.4
BUS module information parameters, bus-specific (P18x)
Zugriff:
Read
only
Parameter
Setting value / Description / Note
Device
Parameter
type
P181
Second Address
(Second Address)
SK TU3-ECT
16 bit
0 ... 4095
Address set with the DIP switch.
P184
SPI error counter
(SPI error counter)
SK TU3-ECT
16 Bit
0 ... 0xFFFF
Counts transmission errors between the ASIC and the SK TU3-ECT processor. This value is set
to 1 as default.