5 Parameter
BU 0570 GB-0312
Subject to technical amendments
29
5.1.3
BUS module information parameters, general (P17x)
Access:
Read
only
Parameter
Setting value / Description / Note
Device
Parameter
type
P170 ...
…
[-02]
Present error
(Present error)
SK TU3-ECT
16 Bit
Current errors in the EtherCAT module. The error message is reset when the supply voltage is
switched off.
Possible error codes:
- 1020 Bus Time Out via P151 (TU4-PNT) or P513 (TU3-PNT)
0 ... 5420
[-01] =
Present module error
[-02] =
Present module error
P171
…
[-01]
…
…
[-03]
Software-Version
(Software Version / Revision)
SK TU3-ECT
16 bit
This parameter shows the software and revision numbers in the module. Array 03 provides
information about any special versions of the hardware or software A zero stands for the
standard version.
0.0 ... 9999.9
[-01] =
Version
[-02] =
Revision
[-03] =
Special version
P172
Configuration
(Configuration level)
SK TU3-ECT
16 bit
The version can be queried in this parameter.
0 ... 2
Possible values:
0 = Internal module
, (SK CU4)
1 = External module
, (SK TU4)
2 = Module SK TU3-PNT
P173
Option status
(Module status)
SK TU3-ECT
16 bit
0 ... 0xFFFF
Explanation of bits:
Bit 0 = Initialisation
Bit 1 = AR installed
Bit 2 = Reserved
Bit 3 = Timeout (P151 / P513)
Bit 4 = Reserved
Bit 5 = Ethernet connection
Bit 6 = Reserved
Bit 7 = Reserved
Bit 8 = Frequency inverter status
Bit 9 = Frequency inverter status
Explanation of frequency inverter status
Bit9 | Bit8
0 0
FI is offline
0 1
FI is not supported
1 0
FI is online