NORD Drivesystems BU0570 User Manual
Page 10
EtherCAT bus module for NORD frequency inverters SK 5xxE
10
Subject to technical amendments
BU 0570 GB-0312
2.2.2
Technical data
Specification
Max. baud rate 100 MBaud
EtherCAT
Electrical isolation 500V
eff
Bus connection
2 RJ45
Bus termination
Performed automatically by the SK TU3-… Technology Unit
Cable
Ethernet CAT-5 or better
Max. cable length
100m between two Ethernet bus modules
Supply voltage
24V
20%, current consumption ≈ 100mA
Reverse polarity protected
Status display
4 LEDs
Device address
via EtherCAT master or setting via 12-pole DIP switches on the rear of the
SK TU3-ECT
PE
Connection via plug pins under the 24V supply
Shield
The shields of the two RJ sockets are connected together and connected to PE with a
high resistance and capacitance. If several technology units are adjacent to each
other, only one board needs to be connected to the PE.
Table 1 Electrical specifications of the SK TU3-…
2.2.3
Connections
Name
Name
45
+24V
46
GND
Table 2 Power supply connections
Signal
Name
RJ45 Pin
TX+
Transmission Data +
1
TX-
Transmission Data -
2
RX+
Receive Data +
3
RX-
Receive Data -
6
Table 3 RJ45 socket connections
Pin 1
Pin 8
24V
GND
SK TU3-…
PE