beautypg.com

Dwyer 2600 User Manual

Page 29

background image

May, 2013

Page 29 of 52

949-1194 Rev. 7

P r o 9

Ramp/Soak: Select O n or O F F
O n

Allows Programmed Ramp/Soak function to be started by the Run/Hold
key on the control front panel.

O F F

Turns Ramp/Soak function O F F and resets program to beginning.

P S E t

Programmer function set: Select O n or O F F .
O F F

Skip Ramp/Soak Programming. Go to next Secondary Menu Item, InPC
(next page).

O n

Enable Ramp/Soak Programming.

S t A t

Programmer Status Display in the Primary Menu when Prog (above) is On:
Select O n or O F F .
O F F

The Primary Menu operates as normal.

O n

The Primary Menu is altered to have the following items inserted before
the SP1 menu item:
#### t i time remaining in active segment
#### ##t i total time in active segment
#### ##S P segment target set point

t b A S

Ramp/Soak Time Base: Select 1 _ S or 6 0 _ S .
1 _ S

Ramp/Soak time base is in 1 second increments. Program time 1 t i ...1 6 t i
is measured in seconds.

6 0 _ S

Ramp/Soak time base is in 60 second increments (minutes). Program
time 1 t i . . . 1 6 t i is measured in minutes.

The following items repeat in the following order: 1 t i , 1 S P , 1 A 1 and 1 A 2 (if A L 1 is
programmed as E U n t ), 2 t i , 2 S P , 2 A 1 , 2 A 2 ,..., 1 6 t i , 1 6 S P , 1 6 A 1 1 6 A 2 ,. To avoid repetition
each item will only be described once.

1 t i

Segment Time: Select 0 to 9 9 9 9 units (minutes if t b A S is set to 6 0 _ S , seconds if
t b A S is set to 1 _ S ).

1 S P

Segment Set Point: Set to target value desired.

1 A 1

Segment Alarm 1 Event: Select O n or O F F .
O n

Alarm 1 is active during segment 1 time (1 t i ).

O F F

Alarm 1 is inactive during segment 1 time (1 t i ).

1 A 2

Segment Alarm 2 Event: Select O n or O F F .
O n

Alarm 2 is active during segment 1 time (1 t i ).

O F F

Alarm 2 is inactive during segment 1 time (1 t i ).

P E n d

Program End action: Select H o l d or O o F F .
H o l d

Stay at the Present Set Point (1 6 S P ).

O o F F

Turn Off SP1 and SP2 Outputs at the end of the program.

L o o P

Repeat program starting at 1 t i .

S P 1

Revert to S P 1 value.