Factory Reset/Clean Boot
THIS PROCEDURE RESETS THE TRIMBLE RANGER TO "FACTORY FRESH" CONDITION AND REMOVES ALL PREVIOUSLY
ADDED SOFTWARE, INCLUDING ANY BADGER METER SOFTWARE APPLICATIONS.
Start the factory reset procedure with the handheld powered on
1 Press and hold the green power key When the countdown timer starts, release the green power key
Result: The Power Menu displays.
2 Tap the Reset button on the Power Menu and immediately press and hold BOTH the green power key AND the
RIGHT key on the handheld keypad
3 When the Clean Boot screen appears, release both the green power key and the RIGHT key
4 Use the up/down navigation arrows on the keypad
to select the Ok button on the screen Then press
the ENTER key on the keypad only if you want to
completely clear the handheld
NOTE:
N
Tapping does not work on the Clean Boot
screen Use the keypad
Result: Several screens display during the next few
seconds: Blank screen, "Scanning...wait" screen,
windows Embedded screen, Finalizing screen, blank
screen again, and then the windows Embedded
screen again.
5 Touch the handheld screen to start the reset process as instructed on the screen
6 Align the touch screen by tapping the cross hairs Continue to tap the cross hairs until the screen aligns
7 At the Password screen, tap Skip
8 Tap the Complete screen to finish the reset
NOTE:
N
After performing a factory reset, the handheld date and time need to be reset Tap Windows Start> Settings>
Clocks & Alarms to set the correct time and date
Press & hold