Requesting historical interval data manually, Historical interval data – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual
Page 27
Historical Interval Data
Whether initiated automatically or manually, the ORION field application software is capable of extracting historical profile
data from an ORION Migratable endpoint at the following intervals:
7 days (Week)
14 days (Two weeks)
30 days (One month)
60 days (Two months)
All readings stored in the endpoint
(Shorter months include extra days of readings, up to 30)
(Up to 90 days of hourly readings or 2160 reads)
This chart shows the number of readings collected for meters set at 60 minute (hourly) intervals and at 15 minute (quarter
hourly) intervals:
Available Profile Data
Extraction Intervals
Hourly Reads:
1 Read per Hour
24 Reads per Day
15 Minute Reads:
4 Reads per Hour
96 Reads per Day
7 days
168 reads (24 x 7)
672 (96 x 7)
14 days
336 reads (24 x 14)
1344 (96 x 14)
30 days
720 reads (24 x 30)
2160 (96 x 22 5)
60 days
1440 reads (24 x 60)
2160 (96 x 22 5)
All/90 days
2160 reads (24 x 90)
2160 reads (96 x 22 5)
NOTE:
N
The ORION Migratable endpoint (or Fixed Network in mobile mode) is capable of holding up to 90 days of hourly
interval data, or 2160 hourly reads If the account is set up to read every 15 minutes – 4 readings per hour –
the data extracted reflects four (4) readings per hour and reaches the maximum 2160 reads in 22 5 days
(90 days / 4 = 22 5 days)
Requesting Historical Interval Data Manually
If a work item was not assigned by the reading data management operator, you can manually initiate a request for the
historical interval data from the current ORION Migratable or Fixed Network (mobile mode) endpoint by performing the
following steps
1 Tap the Work Items button on the account read
screen for an ORION ME account
Result: The work Items screen opens.
NOTE:
N
If a work item is set to be performed
automatically, the message says "Assigned"
and the Collect button is inactive
Figure 36: historical Interval data
REAdINg A ROuTE
Page 27
April 2014