12 examples of configuration 35, Configuration, 8 hard-/software codenumber – West Control Solutions KS 94 User Manual
Page 33: 12 examples of configuration

10.11.8 Hard-/Software Codenumber
The following configuration dates are not changeable. They show the hardware version
(C.991 u. C.992) and the software version (C.993 u. C.994) of the instrument.
Example: 9407 923 31201
Example: 4012 157 25320
10.12
Examples of configuration
Block diagram
Configuration, different from default
9407-9x4-xxxxx
Continuous controller
1 xw- alarm, 2 process value alarms
C.100
C.200
C.500
C.530
CFunc
CTyp
WFunc
Typ
Src
Src
= 10 (continuous)
= 0 (standard controller)
= 0, 1, 4 or 5
= sensor type
= 01(controller output y1)
= 28 (alarm 4)
C.590
C.591
C.600
C.660
C.640
Src
Src
Src
Src
Src
= 25 (alarm 1)
= 26 (alarm 2)
= 02 (xw-alarm)
= 03 (process value x1)
= 03 (process value x1)
9407-9xx-xxxxx
2-pnt. controller +
2 process value alarms
C.100
C.200
C.500
C.590
CFunc
CTyp
WFunc
Typ
Src
Src
= 02 (2-pnt.controller)
= 0 (standard controller)
= 0, 1, 4 or 5
= sensor type
= 01(controller output y1)
= 25 (alarm 1)
C.591
C.660
C.640
Src
Src
Src
= 26 (alarm 2)
= 03 (process value x1)
= 03 (process value x1)
9407-9xx-xxxxx
3-pnt. stepping controller +
process value alarm
C.100
C.200
C.530
C.590
CFunc
CTyp
WFunc
Typ
Src
Src
= 03 (3-pnt.stepping)
= 0 (standard controller)
= 0, 1, 4 or 5
= sensor type
= 01 (controller output y1)
= 02 (controller output y2)
C.591
C.620
Src
Src
= 26 (alarm 2)
= 03 (process value x1)
9407-9x4-xxxxx
Ratio controller (continuous)
1 xw- alarm, 2 process value alarms
C.100
C.180
C.200
C.500
CFunc
CTyp
WFunc
S X2
Typ
Src
= 10 (continuous)
= 1 (ratio controller)
= 0, 1, 4 or 5
= 1 (INP5)
= sensor type
= 01(controller output y1)
C.530
C.590
C.591
C.600
C.660
C.640
Src
Src
Src
Src
Src
Src
= 28 (xw-alarm)
= 25 (alarm 1)
= 26 (alarm 2)
= 02 (xw-alarm)
= 01 (xeff)
= 03 (process value x1)
9407-9x4-1x2xx
Programmer (continuous)
1 xw- alarm
C.100
C.192
C.200
C.500
CFunc
CTyp
WFunc
SPrSt
Typ
Src
= 10 (continuous)
= 1 (standard controller)
= 3 (programmer)
= 1 (di4)
= sensor type
= 01(controller output y1)
C.530
C.591
C.600
Src
Src
Src
= 28 (alarm 4)
= 33 (program end)
= 02 (xw-alarm)
9407-9x4-x1xxx
Continuous contr. ‘split-range’
1 xw- alarm, 1 process value alarm
C.100
C.200
C.500
C.560
CFunc
CTyp
WFunc
Typ
Src
Src
= 11 (continuous split-range)
= 1 (standard controller)
= 0, 1, 4 or 5
= sensor type
= 01(controller output y1)
= 02(controller output y2)
C.590
C.591
C.600
C.660
Src
Src
Src
Src
= 25 (alarm 1)
= 26 (alarm 2)
= 02 (xw-alarm)
= 03 (process value x1)
35
Operating instruction KS94
Configuration
More
INP1
INP5
INP6
INP3
INP4
OUT1
OUT2
OUT4
OUT5
OUT3
x
xw
INP1
INP5
INP6
INP3
INP4
OUT1
OUT2
OUT4
OUT5
OUT3
x
Heizen
INP1
INP5
INP6
INP3
INP4
OUT1
OUT2
OUT4
OUT5
OUT3
x
AUF
ZU
yp
INP1
INP5
INP6
INP3
INP4
OUT1
OUT2
OUT4
OUT5
OUT3
x1
x2
xeff
xw
INP1
INP5
INP6
di4
di5
OUT1
OUT2
OUT4
OUT5
OUT3
x
wp
xw
start/stop
reset
Ende
INP1
INP5
INP6
INP3
INP4
OUT1
OUT2
OUT4
OUT5
OUT3
x
y1
y2
xw