Resistance temperature detector (rtd) and dc mv – West Control Solutions N8100 User Manual
Page 67
Calibration:
Complies with BS4937, NBS125 and IEC584.
Sensor Break Protection:
Break detected within two seconds. Control
outputs set to OFF (0% power); Alarms
operate as if the process variable has
gone over-range.
Resistance Temperature Detector (RTD) and DC mV: Ranges selectable
from front panel (with displayed codes):
Type and Connection:
Three-wire Pt100
Calibration:
Complies with BS1904 and DIN43760.
Lead Compensation:
Automatic scheme.
RTD Sensor Current:
150
µ
A (approximately)
Sensor Break Protection:
Break detected within two seconds. Control
outputs set to OFF (0% power). Alarm
operation is as follows:
S054-A
A-2
59125
Type
Input Range
Dislayed Code
Type
Input Range
Displayed Code
L
0.0 - 205.7
°
C
1815
L
32 - 1403
°
F
1820
L
32.0 - 402.2
°
F
1816
B
211 - 3315
°
F
1934
L
0 - 450
°
C
1817
B
100 - 1824
°
C
1938
L
32 - 841
°
F
1818
N
0 - 1399
°
C
5371
L
0 - 762
°
C
1819
N
32 - 2550
°
F
5324
Input Range
Displayed Code
Input Range
Displayed Code
0 - 800
°
C *
7220
0.0 - 100.9
°
C
2295
32 - 1471
°
F
7221
32.0 - 213.6
°
F
2296
32 - 571
°
F
2229
-200 - 206
°
C
2297
-100.9 - 100.0
°
C
2230
-328 - 402
°
F
2298
-149.7 - 211.9
°
F
2231
-100.9 - 537.3
°
C
7222
0 - 300
°
C
2251
-149.7 - 999.1
°
F
7223