beautypg.com

Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual

Page 45

background image

OPERATION

4

45

MFC 400

www.krohne.com

11/2013 - 4003221901 - AD MFC 400 FF R01 en

DECIMAL

Decimal

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

1

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

104

104

104

104

Flow Velocity

The measured value and status available to the Function

Block.

-

STATUS

Status

R

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_104

RANGE_104

RANGE_104

RANGE_104

Flow Velocity

Range

The high and low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the Primary Value.

-

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated Block Parameter.

NaN

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated Block Parameter.

-NaN

UNITS_INDEX

Units Index

R/W

Device Description units code index for the engineering unit

descriptor for the associated block value.

m/s

Settings:

m/s; mm/s; m/h; km/h; in/s; ft/s; yd/s; in/min; ft/min; yd/min;

in/h; ft/h; yd/h

DECIMAL

Decimal (Point)

R

The number of digits to the right of the decimal point which

should be used by an interface device in displaying the

specified parameter.

0

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

104

104

104

104

Volume Flow

The measured value and status available to the Function

Block.

-

STATUS

Status

R

Digital transducers, unlike their analogue versions, can detect

faults that make the measurement bad or prevent the

actuator from responding. This additional, valuable

information will be passed along with each transmission of a

data value in the form of a status attribute.

-

VALUE

Value

R

A numerical quantity entered by a user or calculated by the

algorithm.

-

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

PRIMARY_VALUE_

RANGE_105

RANGE_105

RANGE_105

RANGE_105

Volume Flow

Range

The high and low range limit values, the engineering units

code and the number of digits to the right of the decimal point

to be used to display the Primary Value.

-

EU_100

max value

R

The engineering unit value which represents the upper end of

range of the associated Block Parameter.

NaN

EU_0

min value

R

The engineering unit value which represents the lower end of

range of the associated Block Parameter.

-NaN

UNITS_INDEX

Units Index

R/W

Device Description units code index for the engineering unit

descriptor for the associated block value.

m³/s

Settings:

m³/s; m³/min; m³/h; m³/d; L/s; L/min; L/h; L/d; kL/s; kL/min;

kL/h; kL/d; mL/min; CFS; CFM; CFH; ft³/d; kCFS; kCFM;

kCFH; kft³/d; cm³/s; cm³/min; cm³/h; cm³/d; gal/s; GPM;

gal/h; gal/d; kgal/s; kgal/min; kgal/h; kgal/d; bbl/s; bbl/min;

bbl/h; bbl/d; ImpGal/s; ImpGal/min; ImpGal/h; ImpGal/d

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value