Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual
Page 22
4
OPERATION
22
MFC 400
www.krohne.com
11/2013 - 4003221901 - AD MFC 400 FF R01 en
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
MAP_29
MAP_29
MAP_29
MAP_29
FD_EXTENDED_
MAP_29
R/W
Field Diagnostics of "F Configuration"
(31) (30) (26) (25)
(21)
Setting:
(02) IO B Binary Output Config / (03) IO B Current In-/Output
Config / (04) IO A Binary Output Config / (05) IO A Current In-
/Output Config. / (10) IO2 Configuration /
(11) IO1 Configuration / (12) Display Config. /
(21) Fieldbus Config. / (25) Density Calibration /
(26) Process Input Config. / (30) DM Configuration / (31) BM
Configuration
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
MAP_30
MAP_30
MAP_30
MAP_30
FD_EXTENDED_
MAP_30
R/W
Field Diagnostics of "F Electronics"
(31) (28) (27) (26)
(21) (16)
Setting:
(01) IO B Failure / (02) IO A Failure / (07) IO 2 Failure / (08) IO 1
Failure / (16) Fieldbus Failure / (21) Process Input Failure /
(26) DM Failure / (27) BM Failure / (28) HW Combination
Error / (31) System Error
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
FD_EXTENDED_
MAP_31
MAP_31
MAP_31
MAP_31
FD_EXTENDED_
MAP_31
R/W
Field Diagnostics of "F Sensor"
(31) (30)
Setting:
(30) Sensor Error / (31) Sensor Containment Dam.
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
FD_MAINT_ACTIVE
Maintenance Active
R
This parameter reflects the error conditions that are being
detected as active as selected for this category. It is a bit
string, so that multiple conditions may be shown. See section
2.9.
Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(02) Config: NoMeas.Value / (08) Electronics : Power Fail /
(09) Process: System Control / (10) Configuration : Totaliser /
(11) Process : Signal Low / (12) Process : 2 Phase Flow /
(13) Process : Signal Search / (14) Electronics : IO
Connection / (15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process /
(29) F Configuration / (30) F Electronics / (31) F Sensor
FD_MAINT_ALM
FD_MAINT_ALM
FD_MAINT_ALM
FD_MAINT_ALM
Fail Maintenance
Alarm
This parameter is used primarily to broadcast a change in the
associated active conditions, which are not masked, for this
alarm category to a Host System.
Unacknowledged
R/W
A discrete enumeration which is set to "Unacknowledged"
when an alarm occurs, and set to "Acknowledged" by a write
from a human interface device or other entity which can
acknowledge that the alarm/event has been noticed.
Uninitialized
Setting:
Uninitialized / Acknowledged / Unacknowledged
Alarm State
R
A discrete enumeration which gives an indication of whether
the alert is active and whether it has been reported.
Uninitialized
Setting:
Uninitialized / Clear - reported / Clear - not reported / Active -
reported / Active - not reported
Time Stamp
R
The time when evaluation of the block was started and a
change in alarm/event state was detected that is unreported.
The time stamp value will be maintained constant until alert
confirmation has been received - even if another change of
state occurs.
Uninitialized
Setting:
MM / DD / YY (Month / Day / Year)
HH:MM:SS (Hour:Minute:Second)
Subcode
R
An enumeration specifying the cause of the alert to be
reported.
-
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value