beautypg.com

Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual

Page 31

background image

OPERATION

4

31

MFC 400

www.krohne.com

11/2013 - 4003221901 - AD MFC 400 FF R01 en

FORMAT_2P_1L

FORMAT_2P_1L

FORMAT_2P_1L

FORMAT_2P_1L

Form. 2.Page 1.Line

R/W

No. of decimal places for 1st line of 2nd page (Fct. C6.4.2).

X.X

Setting:

#X. / #X.X / #X.XX / #X.XXX / #X.XXXX / #X.XXXXX /

#X.XXXXXX / #X.XXXXXXX / #X.XXXXXXXX / automatic

FORMAT_2P_2L

FORMAT_2P_2L

FORMAT_2P_2L

FORMAT_2P_2L

Form. 2.Page 2.Line

R/W

No. of decimal places for 2st line of 2nd page (Fct. C6.4.4).

X.X

Setting:

#X. / #X.X / #X.XX / #X.XXX / #X.XXXX / #X.XXXXX /

#X.XXXXXX / #X.XXXXXXX / #X.XXXXXXXX / automatic

FORMAT_2P_3L

FORMAT_2P_3L

FORMAT_2P_3L

FORMAT_2P_3L

Form. 2.Page 3.Line

R/W

No. of decimal places for 3st line of 2nd page (Fct. C6.4.5).

X.X

Setting:

#X. / #X.X / #X.XX / #X.XXX / #X.XXXX / #X.XXXXX /

#X.XXXXXX / #X.XXXXXXX / #X.XXXXXXXX / automatic

IO_CONNECTION

IO_CONNECTION

IO_CONNECTION

IO_CONNECTION

Status IO Connection

R/W

Defines the influence of the diagnostic ''Electronic : IO

Connection'' (FD_xx_14) to the TB measurements status (Fct.

C1.5.14).

Information

Setting:

Information / Maintenance Required / Function Check / Out Of

Specification / Failure

PASSWRD

PASSWRD

PASSWRD

PASSWRD

Password

R/W

Password to activate access rights to restricted parameters.

0

POWER_FAILURE

POWER_FAILURE

POWER_FAILURE

POWER_FAILURE

Status Power Failure

R/W

Defines the influence of the diagnostic ''Electronic : Power

Failure'' (FD_xx_8) to the TB measurements status (Fct.

C1.5.13).

Information

Setting:

Information / Maintenance Required / Function Check / Out Of

Specification / Failure

PROTECT_INFO

PROTECT_INFO

PROTECT_INFO

PROTECT_INFO

Access protection

R

Current protection level to restricted parameters.

Production

Setting:

Concentration / bit 5…6: not use / User / Service level /

Production / Custody Transfer / Write Lock

SERIAL_NUMBER

SERIAL_NUMBER

SERIAL_NUMBER

SERIAL_NUMBER

Serial Number

R

Device serial number, serial number of the system.

Current serial

number

SIGNAL_LOW

SIGNAL_LOW

SIGNAL_LOW

SIGNAL_LOW

Status Signal Low

R/W

Defines the influence of the diagnostic ''Process : Signal Low''

(FD_xx_11) to the TB measurements status (Fct. C1.5.7).

Information

Setting:

Information / Maintenance Required / Function Check / Out Of

Specification / Failure

SIGNAL_SEARCH

SIGNAL_SEARCH

SIGNAL_SEARCH

SIGNAL_SEARCH

Status Signal Search

R/W

Defines the influence of the diagnostic ''Process : Signal

Search'' (FD_xx_13) to the TB measurements status (Fct.

C1.5.8).

Information

Setting:

Information / Maintenance Required / Function Check / Out Of

Specification / Failure

SYSTEM_CONTROL

SYSTEM_CONTROL

SYSTEM_CONTROL

SYSTEM_CONTROL

Status System Control

R/W

Defines the influence of the diagnostic ''Process : System

Control'' (FD_xx_9) to the TB measurements status (Fct.

C1.5.11).

Information

Setting:

Information / Maintenance Required / Function Check / Out Of

Specification / Failure

SW_SIMULATE

SW_SIMULATE

SW_SIMULATE

SW_SIMULATE

SW simulate

R/W

Enable/disable simulation like simulate Hardware jumper.

Disable

Setting:

Disable / Active

Parameter

Parameter

Parameter

Parameter
DD name

Access

Description and settings

Initial Value