Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual
Page 44
4
OPERATION
44
MFC 400
www.krohne.com
11/2013 - 4003221901 - AD MFC 400 FF R01 en
Update State
R
A discrete enumeration which gives an indication of whether
the alert has been reported.
Uninitialized
Setting:
Uninitialized / Update reported / Update not reported
Time Stamp
R
The time when evaluation of the block was started and a
change in alarm/event state was detected that is unreported.
The time stamp value will be maintained constant until alert
confirmation has been received - even if another change of
state occurs. Time stamp records the time when parameter
was updated.
Uninitialized
Setting:
MM / DD / YY (Month / Day / Year)
HH:MM:SS (Hour:Minute:Second)
Static Revision
R
The static revision of the block whose static parameter was
changed and is being reported. It is possible for the present
value of static revision to be greater than this because static
can be changed at any time.
0
Setting:
0…65535
Relative Index
R
The OD index of the static parameter whose change caused
this alert, minus the FB starting index. If the update event was
caused by a write to multiple parameters at the same time,
then this attribute will be zero.
0
Setting:
0…65535
COLLECTION_
COLLECTION_
COLLECTION_
COLLECTION_
DIRECTORY
DIRECTORY
DIRECTORY
DIRECTORY
Collection
Directory
A directory that specifies the number, starting indices and DD
Item IDs of the data collections in each transducer within a
Transducer Block.
-
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
TYPE
TYPE
TYPE
TYPE
Primary Value
Type
R
The type of measurement represented by the primary value.
For example: mass flow, absolute pressure, differential
temperature
Mass
PRIMARY_VALUE
PRIMARY_VALUE
PRIMARY_VALUE
PRIMARY_VALUE
Mass Flow
The measured volume flow value and status available to the
Function Block.
-
STATUS
Status
R
Digital transducers, unlike their analogue versions, can detect
faults that make the measurement bad or prevent the
actuator from responding. This additional, valuable
information will be passed along with each transmission of a
data value in the form of a status attribute.
-
VALUE
Value
R
A numerical quantity entered by a user or calculated by the
algorithm.
-
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
PRIMARY_VALUE_
RANGE
RANGE
RANGE
RANGE
Mass Flow range
The high and low range limit values, the engineering units
code and the number of digits to the right of the decimal point
to be used to display the Primary Value.
-
EU_100
max value
R
The engineering unit value which represents the upper end of
range of the associated Block Parameter.
NaN
EU_0
min value
R
The engineering unit value which represents the lower end of
range of the associated Block Parameter.
-NaN
UNITS_INDEX
Units Index
R/W
Device Description units code index for the engineering unit
descriptor for the associated block value.
kg/h
Settings:
kg/s; kg/min; kg/h; kg/d; t/s; t/min; t/h; t/d; g/s; g/min; g/h;
g/d; lb/s; lb/min; lb/h; lb/d; klb(US)/s; klb(US)/min; klb(US)/h;
klb(US)/d; STon/s; STon/min; STon/h; STon/d; LTon/s;
LTon/min; LTon/h; LTon/d
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value