OPERATION
32
MFC 400
www.krohne.com
11/2013 - 4003221901 - AD MFC 400 FF R01 en
TWO_PHASE_FLOW
TWO_PHASE_FLOW
TWO_PHASE_FLOW
TWO_PHASE_FLOW
Status 2 Phase Flow
R/W
Defines the influence of the diagnostic ''Process : 2 Phase
Flow"' (FD_xx_12) to the TB measurements status (Fct.
C1.5.10).
Information
Setting:
Information / Maintenance Required / Function Check / Out Of
Specification / Failure
Variable_2P_1L
Variable_2P_1L
Variable_2P_1L
Variable_2P_1L
Disp. 2.Page 1.Line
R/W
Select the Function Block output value to display at 2nd page
1st line (Fct. C6.4.1).
AI1
Setting:
AI1 / AI2 / AI3 / AI4 / AI5 / AI6 / PID / IT1 / IT2
Variable_2P_2L
Variable_2P_2L
Variable_2P_2L
Variable_2P_2L
Disp. 2.Page 2.Line
R/W
Select the Function Block output value to display at 2nd page
2nd line (Fct. C6.4.3).
AI2
Setting:
AI1 / AI2 / AI3 / AI4 / AI5 / AI6 / PID / IT1 / IT2
Variable_2P_3L
Variable_2P_3L
Variable_2P_3L
Variable_2P_3L
Disp. 2.Page 3.Line
R/W
Select the Function Block output value to display at 2nd page
3rd line (Fct. C6.4.5).
AI3
Setting:
AI1 / AI2 / AI3 / AI4 / AI5 / AI6 / PID / IT1 / IT2
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value