Operation – KROHNE MFC 400 FOUNDATION FIELDBUS User Manual
Page 27
OPERATION
4
27
MFC 400
www.krohne.com
11/2013 - 4003221901 - AD MFC 400 FF R01 en
DIAGNOSTIC_
DIAGNOSTIC_
DIAGNOSTIC_
DIAGNOSTIC_
SIMULATE_VALUE
SIMULATE_VALUE
SIMULATE_VALUE
SIMULATE_VALUE
Diagnostic Simulate
Value
R/W
Allows the conditions to be manually supplied when
simulation is enabled. The simulate jumper is required for
simulation to be enabled.
Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(02) Config: NoMeas.Value / (08) Electronics : Power Fail /
(09) Process: System Control / (10) Configuration : Totaliser /
(11) Process : Signal Low / (12) Process : 2 Phase Flow /
(13) Process : Signal Search / (14) Electronics : IO
Connection / (15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process /
(29) F Configuration / (30) F Electronics / (31) F Sensor
DIAGNOSTIC_VALUE
DIAGNOSTIC_VALUE
DIAGNOSTIC_VALUE
DIAGNOSTIC_VALUE
Diagnostic Value
R
Current field diagnostic condition.
Uninitialized
Setting:
(00) Check / (01) Electronics : Operation Info /
(02) Config: NoMeas.Value / (08) Electronics : Power Fail /
(09) Process: System Control / (10) Configuration : Totaliser /
(11) Process : Signal Low / (12) Process : 2 Phase Flow /
(13) Process : Signal Search / (14) Electronics : IO
Connection / (15) Process : Current input / (16) M Process /
(17) M Configuration / (18) M Electronics / (19) M Sensor /
(20) S Process / (21) S Configuration / (22) S Electronics /
(23) S Sensor / (24) C Process / (25) C Configuration /
(26) C Electronics / (27) C Sensor / (28) F Process /
(29) F Configuration / (30) F Electronics / (31) F Sensor
ENABLE_DISABLE
ENABLE_DISABLE
ENABLE_DISABLE
ENABLE_DISABLE
Simulate En/Disable
R/W
Enable/disable simulation.
Uninitialized
Setting:
Uninitialized / Disabled / Active
FD_VER
FD_VER
FD_VER
FD_VER
Revision
R
The major version of the Field Diagnostics specification used
for the development of this device.
1
FEATURES
FEATURES
FEATURES
FEATURES
Features
R
Used to shows supported resource block options.
Reports
Faultstate
Soft W Lock
Multi-bit Alarm
(Bit-Alarm)
Support
Setting:
Reports / Faultstate / Soft W Lock /
Multi-bit Alarm (Bit-Alarm) Support
FEATURES_SEL
FEATURES_SEL
FEATURES_SEL
FEATURES_SEL
Features Selection
R/W
Used to select resource block options.
Reports
Soft W Lock
Setting:
Reports / Faultstate / Soft W Lock /
Multi-bit Alarm (Bit-Alarm) Support
FREE_SPACE
FREE_SPACE
FREE_SPACE
FREE_SPACE
Free Space
R
Percent of the memory available for further configuration.
Zero in a preconfigured resource.
0.0
Setting:
0.0…100.0
FREE_TIME
FREE_TIME
FREE_TIME
FREE_TIME
Free Time
R
Percent of the block processing time that is free to process
additional blocks.
0.0
Setting:
0.0…100.0
GRANT_DENY
GRANT_DENY
GRANT_DENY
GRANT_DENY
Grant Deny
R/W
Options for controlling access of host computers and local
control panels to operating, tuning and alarm parameters of
the block.
-
Parameter
Parameter
Parameter
Parameter
DD name
Access
Description and settings
Initial Value