C. Advanced setup
B.2.7
Custom.
Length Unit
Non-standard length unit for the
conversion table. This is defined by the
supervisor. Go to Supervisor >
Supervisor >
Supervisor >
Supervisor >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Display Settings > Custom. Length Unit
Display Settings > Custom. Length Unit
Display Settings > Custom. Length Unit
Display Settings > Custom. Length Unit
or follow the procedure in the
Conversion
Conversion
Conversion
Conversion setup menu.
Read only
B.2.9
Custom. Conv.
Unit
Non-standard conversion unit for the
conversion table. This is defined by the
supervisor. Go to Supervisor >
Supervisor >
Supervisor >
Supervisor >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Advanced Setup > Device Setup >
Display Settings > Custom. Conv. Unit
Display Settings > Custom. Conv. Unit
Display Settings > Custom. Conv. Unit
Display Settings > Custom. Conv. Unit
or follow the procedure in the
Conversion
Conversion
Conversion
Conversion setup menu.
Read only
Menu
No.
Function
Function description
Selection list
Default
C.1 Installation Setup
C.1.1
Installation
Type
The installation on the tank for the
device.
Metal Tank, Plastic Tank,
Free Air Application
Metal Tank
C.1.2
Tank Height /
Measuring
Range
"Tank height" is the distance from the
tank connecting flange face/thread
stop to the tank bottom. "Measuring
range" (for "Free Air Application" only)
is the maximum distance that the
device must measure.
min-max:
0.20…80 m / 0.66…262 ft
20 m / 65.61 ft
C.1.3
Application
Type
The conditions in which the device is
used. If the surface of the product is
flat, select "Storage". If the surface of
the product is disturbed, select
"Process". If the surface of the product
is agitated with vortexes and foam,
select "Agitator". If the device is
installed in a still well, select
"...+Stillwell".
Process, Storage, Agitator,
Process+Stillwell,
Storage+Stillwell,
Agitator+Stillwell
Process or
Process+
Stillwell
The conditions in which the device is
used. For free air applications only. If
the surface of the product is flat, select
"No Disturbance". If the surface of the
product is disturbed, select "Medium
Disturbance". If there are bubbles on
the surface of the product and also
vortexes and foam, select "Heavy
Disturbance".
No Disturbance, Medium
Disturbance, Heavy
Disturbance
No Disturbance
C.1.4
Stillwell Height
The height of the stillwell. This is
available if you set "...+Stillwell" in
item C.1.3 Application Type.
min-max:
0…80 m / 0…262 ft
10 m / 32.81 ft
C.1.5
Stillwell
Diameter
The inner diameter of the stillwell. This
is available if you set "...+Stillwell" in
item C.1.3 Application Type.
min-max:
8…200 mm / 0.31…7.88¨
100 mm / 3.94¨
C.1.6
Antenna
Extension
Optional antenna extension. These are
attached between the flange and the
antenna. Each part is 105 mm / 4.1¨
long.
min-max:
0…5000.00 mm / 0…196.85¨
0 mm / 0¨
C.1.7
Distance Piece
Optional distance piece between the
converter and the process connection.
min-max:
0…5000.00 mm / 0…196.85¨
0 mm / 0¨