beautypg.com

Operation – KROHNE OPTIWAVE 7300C EN User Manual

Page 59

background image

OPERATION

6

59

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000172405 - HB OPTIWAVE 7300 R07 en

Sub-

menu

Conversion

submenu [Mass]

[Mass]

[Mass]

[Mass]

-

1

Do you want to use

a free unit?

Yes, No

No

2

Table Length Unit

m, cm, mm, inch, ft,

Free Unit

m

3

Please select

Volume / Mass

Select "Mass".

Mass

4

Do you want to use

the density of the

product?

Yes, No

Yes

5

Product Density

The Wizard adds this step if you

select "Yes" in step 4.

min-max: 0…20000 kg/m3

0

6

Tank Shapes

The Wizard adds this step if you

select "Yes" in step 4. This sub-

procedure uses the

information given here to find

the volume. You have to type in

the tank shape, height, width

and length.

...

...

7

Conversion Unit

The conversion unit is given as

a volume if the product density

is given. If not, choose a mass

unit.

m³, L, US gal, GB gal, ft³, bbl

or Tons, kg, US Tons, GB

Tons

m³ or Tons

8

Mass Table

A table that converts product

level to product mass. If you

selected "Yes" in step 4, make

entries in the table in volume

units. Push[

] or [

] to select

a line and push [>>>>] to change

values automatically supplied

by the device.

Sub-

menu

Conversion

submenu

[Free Unit]

[Free Unit]

[Free Unit]

[Free Unit]

If you cannot find the units or

tank shape in the menu, you

can customize the conversion

table.

-

1

Do you want to use

a free unit?

Select "Yes".

Yes, No

No

2

Custom. Length

Unit

A non-standard length unit for

the conversion table. This is

defined by the supervisor.

LEN_

FREE_

3

Custom. Length

Ratio

The conversion factor between

the length unit selected in

C.5.1.4 (length unit) and C.5.1.7

(customer length unit). This

ratio is a multiple of 1 mm.

min-max: 1…99999

1

4

Custom. Conv. Unit A non-standard conversion unit

for the conversion table. This is

defined by the supervisor.

CO_FR_UN

5

No. of Entries

The number of lines in the

conversion table.

min-max: 0…50

2

6

Volume/Mass

Table

A table that converts product

level to another physical

parameter. Push[

] or [

] to

select a line and push [>>>>] to

change values automatically

supplied by the device.

Menu
No.

Step

Function

Function description

Selection list

Default