START-UP

5

45

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000172405 - HB OPTIWAVE 7300 R07 en

5.1 Start-up checklist

Check these points before you energize the device:

• Are all the wetted components (antenna, flange and gaskets) resistant to the product in the

tank?

• Does the information on the signal converter nameplate agree with the operating data?
• Did you correctly install the device on the tank?
• Do the electrical connections agree with the national electrical codes? Use the applicable

electrical cables with the cable glands.

5.2 Operating concept

You can read measurements and configure the device with:

• A digital display screen (optional).
• A connection to a system or PC with PACTware™. You can download the Device Type

Manager (DTM) file from the website. It is also supplied on the DVD-ROM delivered with the
device.

• A connection to a system or PC with AMS™. You can download the Device Description (DD)

file from the website. It is also supplied on the DVD-ROM delivered with the device.

• A connection to a HART

®

Field Communicator. You can download the Device Description (DD)

file from the website. It is also supplied on the DVD-ROM delivered with the device.

DANGER!
Before you energize the device, make sure that the supply voltage and polarity are correct.

DANGER!
Make sure that the device and the installation agrees with the requirements of the Ex certificate