6

OPERATION

58

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000172405 - HB OPTIWAVE 7300 R07 en

A.1.3

A.1.3

A.1.3

A.1.3

Empty Spectrum

Empty Spectrum

Empty Spectrum

Empty Spectrum

Fixed and moving objects in the

Fixed and moving objects in the

Fixed and moving objects in the

Fixed and moving objects in the

tank cause interference

tank cause interference

tank cause interference

tank cause interference

signals. Put them through this

signals. Put them through this

signals. Put them through this

signals. Put them through this

filter to correctly measure the

filter to correctly measure the

filter to correctly measure the

filter to correctly measure the

tank contents.

tank contents.

tank contents.

tank contents.

1

Do you have a

completely filled

tank?

If the tank is full, it is not

possible to complete this

procedure. The tank must be

partially filled or empty.

Yes, No

Yes

2

Are all moving

parts in the tank,

e.g. agitators, in

motion?

We recommend that you switch

on agitators and other moving

equipment to filter all

interference signals.

Yes, No

Yes

3

Is your tank

partially filled or

empty?

If the tank is partially filled, the

device must include the tank

contents when it filters the

signal.

Partially Filled, Empty

Partially

Filled

4

Distance

If the tank is partially filled,

type in a distance shorter than

that between the flange and

the tank contents.

min-max:

0…tank height

10 m /

32.808 ft

5

Do you want to

consider Average

or Maximum value

for recording?

Use the average value for tanks

which contain fixed objects

only. Use the maximum value

for tanks which contain many

objects or moving objects.

Average, Maximum

Average

6

Empty spect.

recording is in

progress

7

Empty spectrum

graph

8

Do you want to

save the

spectrum?

If you save this data, the device

will use it when it measures

the tank contents.

Save, Cancel

3

Save

A.1.4

A.1.4

A.1.4

A.1.4

Conversion

Conversion

Conversion

Conversion

Follow this procedure to set

Follow this procedure to set

Follow this procedure to set

Follow this procedure to set

the device up to display

the device up to display

the device up to display

the device up to display

readings in volume, mass or

readings in volume, mass or

readings in volume, mass or

readings in volume, mass or

user-defined units.

user-defined units.

user-defined units.

user-defined units.

Sub-

menu

Conversion

submenu [Volume]

[Volume]

[Volume]

[Volume]

1

Do you want to use

free unit?

Select "No".

Yes, No

No

2

Table Length Unit

m, cm, mm, inch, ft, Free

Unit

m

3

Please select

Volume / Mass

Select "Volume".

Volume, Mass

5

Tank Shapes

This sub-procedure uses the

information given here to find

the volume. You have to type in

the tank shape, height, width

and length.

...

...

6

Conversion Unit

The displayed unit in operator

mode.

m3, L, US gal, GB gal, ft3,

bbl

m3

7

Volume Table

A table that converts product

level to product volume.

Push[

] or [

] to select a line

and push [>>>>] to change values

automatically supplied by the

device.

Menu
No.

Step

Function

Function description

Selection list

Default