beautypg.com

Installation – KROHNE OPTIWAVE 7300C EN User Manual

Page 33

background image

INSTALLATION

3

33

OPTIWAVE 7300 C

www.krohne.com

03/2014 - 4000172405 - HB OPTIWAVE 7300 R07 en

Tri-Clamp

®

Equipment needed:

• Device
• Gasket (not supplied)
• Band clamp (not supplied)

How to attach a device with a Tri-Clamp

®

connection

• Make sure that the tank connection is level.
• Make sure that you use the applicable gasket for the connection dimensions and the process.
• Align the gasket correctly.
• Lower the antenna carefully into the tank.
• Attach the band clamp to the process connection.
• Tighten the band clamp.

Figure 3-18: Tri-Clamp

®

connection

1 Tank socket
2 Band clamp