3-48

BHK-MG (OPR) 022014

FIGURE 3-18. ANALOG PROGRAMMING OF OUTPUT CURRENT (CURRENT MODE) OR CURRENT

LIMIT (VOLTAGE MODE) USING CURRENT SOURCE (1mA) (CS)

The external current source is applied to the inverting input of the uncommitted amplifier which
is configured as a current-voltage converter.

CAUTION

Observe the following to avoid damage to the power supply. The external current source
output must be isolated from ground (floating output), or be powered from an a-c source that is