3-3

MENU

Command Entry

Press to enter Menu commands: press repeatedly to scroll through Menu func-
tions: (1) set LCD contrast, (2) GPIB address, (3) Baud Rate, (4) Loop Back
Test, (5) DCL control, (6) Power-Up Digital DC Output on/off, (7) speaker on/off,
(8) change calibration password, (9) restore previous calibration values,
(10) restore factory calibration values, (11) view firmware version number,
(12) set Power-up and RESET current, (13) set maximum voltage, (14) set max-
imum current, (15) current scale. Press ENTER, RESET or CLEAR to exit
Menu.

(1) 3.2.5,
(2) 3.3.3,
(3) 3.4.1
(4) 3.4.4
(5) 3.3.2
(6) 3.2.7.4
(7,)3.2.6,
(8) 4.5,
(9) 4.6,
(10) 4.7
(11) 3.2.15
(12) 3.2.8.1
(13, 14) 3.2.12,
(15) 3.2.10

OV SET

7

Command Entry

Press to set overvoltage protection value. Data entry required to enter the over-
voltage protection value; press ENTER to accept displayed value.

3.2.11

Data Entry

Press to enter number 7.

3.2.1.2

OC SET

8

Command Entry

Press to set overcurrent protection value. Data entry required to enter new over-
current protection value; press ENTER to accept displayed value.

3.2.11

Data Entry

Press to enter number 8.

3.2.1.2

CALIB

9

Command Entry

Press to enter Calibration status. Requires password entry; instructions appear
on LCD.

4.3

Data Entry

Press to enter number 9.

3.2.1.2

STORE

Command Entry

Press to store present values of output voltage and current and overvoltage and
overcurrent protection. Data entry required to select memory location where val-
ues are to be stored

3.2.13

EDIT

PROG

Command Entry

Press to select the starting memory location to be edited. Then use

or

to

view or modify the parameters of a specific memory location or to create a new
program.

3.2.16.1

STEP

4

Command Entry

Press to select starting address of program to be executed one step at a time.
Address is updated each time STEP is pressed.

3.2.16.3

Data Entry

Press to enter number 4.

3.2.1.2

TIME

5

Command Entry

Press to edit time value for specific memory location. Select memory location
(data entry), then enter time value, 0.01 to 655.35 seconds (data entry).

3.2.16.1.1

Data Entry

Press to enter number 5.

3.2.1.2

RUN

6

Command Entry

Press to run a program. Requires data entry to select starting location. Press
ENTER to accept displayed value.

3.2.16.2

Data Entry

Press to enter number 6.

3.2.1.2

RECALL

Command Entry

Press to recall previously stored values of output voltage and current, and over-
voltage and overcurrent protection. The previously stored output state (enabled
or disabled) will also be recalled. Data entry required to select memory location
containing values to be recalled; press ENTER to accept displayed value.

3.2.14

CLEAR

Data Entry

Press to exit Data Entry status; any numbers entered are lost. Restores Com-
mand Entry status

3.2.9

1

Data Entry

Press to enter number 1.

3.2.1.2

TABLE 3-2. KEY FUNCTIONS (CONTINUED)

KEY

POWER SUPPLY

STATUS ACTIVE

DESCRIPTION

REFERENCE

PARAGRAPH