beautypg.com

B.43 [source:]current:mode? query, B.44 [source:]current:protection[:level] command, B.45 [source:]current:protection[:level]? query – KEPCO BHK-MG 200W (Full Rack) Series User Manual

Page 141: B.46 [source:]current:range command, B.47 [source:]current:range? query, B.43, Sourc, B.44, B.45, B.46

background image

BHK-MG (OPR) 022014

B-11

B.43 [SOURce:]CURRent:MODE? QUERY

CURR:MODE?

Syntax:

Short Form: [SOUR:]CURR[:LEV]:MODE?
Long Form: [SOURce:]CURRent[:LEVel]:MODE?
Return value: FIXED or LIST

Description: Identifies active voltage mode. Returns LIST while list is being executed. Returns FIXED while in

fixed (default) mode of operation. Related Commands: LIST commands. (See example, Figure B-3.)

B.44 [SOURce:]CURRent:PROTection[:LEVel] COMMAND

CURR:PROT

Syntax:

Short Form: [SOUR:]CURR:PROT[:LEV]
Long Form: [SOURce:]CURRent:PROTection[:LEVel]
= digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1

Description: Sets overcurrent protection level for power supply. If the value is out of the acceptable overcurrent

range for the power supply model, error message -222,”Data out of range” is posted in the output
queue. If the power supply output exceeds the current protection level programmed, the power supply
circuit breaker trips. (See example, Figure B-4.)

B.45 [SOURce:]CURRent:PROTection[:LEVel]? QUERY

CURR:PROT?

Syntax:

Short Form: [SOUR:]CURR:PROT[:LEV]? {MIN | MAX}
Long Form: [SOURce:]CURRent:PROTection[:LEVel]? {MIN | MAX}
Return Value: = digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1

Description: Returns value representing current protection level.CURR:PROT? returns value set by

CURR:PROT. CURR:PROT? MAX returns maximum current protection value (see Table 1-2). This
value is determined at the factory and cannot be changed by the user. CURR:PROT? MIN returns the
minimum current protection value (always 0). (See example, Figure B-4.)

Description: Returns the current value established by CURR:TRIG command. (See example, Figure B-1.)

B.46 [SOURce:]CURRent:RANGe COMMAND

CURR:RANG

Syntax:

Short Form: [SOUR:]CURR:RANG:LOW or [SOUR:]CURR:RANG:UPP
Long Form: [SOURce:]CURRent:RANGe:LOWer or [SOURce:]CURRent:RANGe:UPPer

Description: Selects high scale or low scale Current range. CURR:RANG:LOW selects Low scale,

CURR:RANG:UPP selects High scale. Low scale = Io

MAX

/10, High scale = Io

MAX

. Refer to PAR.

3.2.10 for complete description.

B.47 [SOURce:]CURRent:RANGe? QUERY

CURR:RANG?

Syntax:

Short Form: [SOUR:]CURR:RANG?

Long Form: [SOURce:]CURRent:RANGe?

Return Value: 0 or 1

Description: Identifies current scale selected. Returns 0 for low scale, 1 for high scale.

B.48 [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude] COMMAND

CURR:TRIG

Syntax:

Short Form: [SOUR:]CURR[:LEV]:TRIG[:AMP]
Long Form: [SOURce:]CURRent[:LEVel]:TRIGgered[:AMPlitude]
= digits with decimal point and Exponent, e.g., 2.71E+1 for 27.1

Description: Programs current value to be transferred to output by *TRG commands. Actual output current

will depend on load conditions. If the value exceeds the CURR:LIM[:HIGH] value, error message -
222,”Data out of range” is posted in output queue. Related Commands: CURR. (See example, Figure
B-1.)