beautypg.com

GW Instek GDS-800 Series Programming Manual User Manual

Page 24

background image

GDS-806/810/820/840 Programming Manual

23

*WAI (no query form)

WAI prevents the programming instrument from executing further commands or

queries until all pending operations finish.

Syntax

*WAI

:ACQuire:AVERage

Select the average number of waveform acquisition. The range for averaging is

from 2 to 256 in powers of 2.

Note: Before implement this instrument, please apply “:ACQuire:MODe 2” in

advance!

Syntax

:ACQuire:AVERage {1|2|3|4|5|6|7|8}

:ACQuire:AVERage?

Arguments

1

→Average number is 2

2

→Average number is 4

3

→Average number is 8

4

→Average number is 16

5

→Average number is 32

6

→Average number is 64

7

→Average number is 128

8

→Average number is 256

Returns