(10) For United Kingdom

NOTE

This lead/appliance must only be
wired by competent persons.

WARNING

THIS APPLIANCE MUST BE

EARTHED

IMPORTANT

The wires in this lead are
coloured in accordance with the
following codes:

Green/Yellow
Blue
Brown

:Earth
:Neutral
:Live

(Phase)

As the colours of the wires in mains leads may not correspond with the

coloured markings identified in your plug/appliance, proceed as follows:

The wire which is coloured Green and Yellow must be connected to the

Earth terminal marked with the letter E or by the earth symbol

or

coloured Green or Green and Yellow.

The wire which is coloured Blue must be connected to the terminal which

is marked with the letter N or coloured Blue or Black.

The wire which is coloured Brown must be connected to the terminal

marked with the letter L or P or coloured Brown or Red.

If in doubt, consult the instructions provided with the equipment or contact

the supplier.

This cable/appliance should be protected by a suitably rated and

approved HBC mains fuse; refer to the rating information on the

equipment and/or user instructions for details. As a guide, cable of

0.75mm

2

should be protected by a 3A or 5A fuse. Larger conductors

would normally require 13A types, depending on the connection method

used.

Any moulded mains connector that requires removal/replacement must be

destroyed by removal of any fuse and fuse carrier and disposed of

immediately, as a plug with bared wires is hazardous if engaged in a live

socket. Any re-wiring must be carried out in accordance with the

information detailed in this section.